How to Vent Basement Kitchen Sink

If you are looking for instructions on how to vent basement Nivito, you are in luck! Here are a few things you should keep in mind. First, check the vent rise and angle. The angle must be upward, but should not slope down. Also, be sure to place the vent rise at the same height as the existing pipe. After you have checked the angle, cut the pipe to match the existing one, and then glue it in place.


The vent must be installed between the waste line and the P-trap. Depending on the waste line diameter, the distance should be at least two and a half feet. For example, a one and a half inch waste line will need a vent distance of two and a half feet, while a three-foot-diameter pipe will need a vent stack at least three feet away.


Install a sanitary tee


Another method is to install a sanitary tee before the drain pipe drops vertically. This will allow for the proper vent angle. You can also use parallel ports or a perpendicular port that are glued to the waste line. If you want a completely new vent, you can install a threaded plug in the existing clean out.


Install an air admittance valve


You can also install an air admittance valve (AAV) to vent your basement sink. This type of vent is used in areas that are too small to use a traditional vent. Installing an AAV is easy and requires little maintenance. You should check the state building code before installing it.


A downdraft range should never be installed in a basement because it will backdraft the water heater or furnace. If you have a ducted exhaust fan, you should install it at a higher location. Moreover, you should have it inspected by a local plumbing inspector. A downdraft range can cause an explosion or fire.


Check the measurements


Before installing an AAV, you need to check the measurements of the sink. The lowest part of the pipe should be about four inches above the floor level, and the top should fit underneath the sink. It is crucial to make sure all components fit together before adding glue. Marking the positions of all parts will help you install the AAV correctly.


When venting a sink in a basement, you need to ensure the ventilation pipe meets local building codes. The pipe should be sized according to the amount of water and the type of sink. If the drain pipe runs parallel to the floor, you need to run a Y-shaped vent pipe. The vent pipe should slope upward at an angle of about 45 degrees.


The floor drain should be kept clear of small particles, especially when it is used infrequently. These particles can clog the drain system and cause the basement to flood.